Carving machine
Kinda frequency inverter applied in carving machine
1, Load feature
(1) It is used to drive high speed motor, the maximum speed is about 24000RPM, correspond to 400Hz, the minimum speed is
about 2000RPM.
(2) It needs high torque at low speed.
2, Requests for frequency inverters (VFD)
(1) Wide range of operation frequency.
(2) It needs multi-points V/f carve, which can control the output torque at different speed.
(3) An external input ON/OFF signal will be used to start and stop the frequency inverter, an external input analog signal will be used
to control the output frequency and it needs fault reset input signal and fault output signal.
3, Instruction for commissioning
(1) Pictures of carving machine
Take 400Hz, 380V and 24000RPM carving machine as example.
No. | Function codes | Default | Setting value | Explanation |
1 | F0-02 | 0 | 1 | External start / stop signal |
2 | F0-03 | 1 | 2 | External VI signal (analog signal) to control the output frequency |
3 | F5-00 | 1 | 1 | Start |
4 | F5-11 | 0 | 11 | Two-line mode 2 |
5 | F5-02 | 0 | 9 | Fault reset |
6 | F6-02 | 2 | 2 | Fault output |
7 | F8-13 | 0 | 1 | Reverse forbidden |
8 | F0-10 | 50 | 400 | Maximum frequency 400Hz |
9 | F0-12 | 50 | 400 | Upper limit frequency 400Hz |
10 | F2-04 | 50 | 400 | Motor rated frequency 400Hz |
11 | F2-05 | Model depend | 24000 | Motor rated RPM |
12 | F4-00 | 0 | 1 | Multi-points V/f carve |
13 | F4-02 | 50 | 400 | Torque boost cutoff frequency (400Hz) |
14 | F4-03 | 0 | 0 | V/f frequency point 1 (0Hz) |
15 | F4-04 | 0% | 2.0~4.0% | V/f voltage point 1 |
16 | F4-05 | 0 | 100 | V/f frequency point 2 (100Hz) |
17 | F4-06 | 0% | 26~30% | V/f voltage point 2 |
18 | F4-07 | 0 | 300 | V/f frequency point 3 (300Hz) |
19 | F4-08 | 0% | 75~80% | V/f voltage point 3 |
(3) Typical wiring diagram
(1) To ensure the over current fault will not happen, the multi-points V/f setting in F4 group should be set base on real requests, the
voltage points and frequency points should follow the rule of V/f1< V/f2< V/f3, and the voltage at low frequency cannot be set too
big.
(2) The motor’s parameters on the nameplate of carving machine should be set correctly in F2 group.